For the PRI Gateway, digital trunk loop and D-channel configuration is not
supported on TMDI card types.
nB+D PRI is supported by the PRI Gateway but is not shown in these
examples.
Use
using LD 17" (page 81)
the PRI Gateway.
Procedure 19
Configuring a D-channel interface to support PRI/NI2 using LD 17
Step
1
2
3
4
5
6
Table 16
PRI/NI2 D-channel interface configuration (LD 17)
Prompt
Response
REQ
CHG
TYPE
ADAN
ADAN
NEW DCH xx
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
Note: For the PRI Gateway, a patch to allow the use of port 0 or port 1
is provided in CS 1000 Release 5.0. See the DEP list.
Procedure 19 "Configuring a D-channel interface to support PRI/NI2
Action
Log on to the CS 1000E.
Enter the command:
LOGI
System response:
USERID?
Enter the default username:
admin1 or admin2
System response:
PASS?
Enter the default password:
0000
Access LD 17. Enter the command:
LD 17
Enter the responses shown in
configuration (LD 17)" (page
Description
Change existing data.
Action device and number.
Add a D-channel on logical port 0 - 255.
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
Configure E1/T1 ports on a Call Server 81
to configure the PRI/NI2 D-channel interface in
Table 16 "PRI/NI2 D-channel interface
81).