124 Maintenance and diagnostics
Figure 30
PRI startup
2
3
4
5
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
In
Figure 30 "PRI startup" (page
(For the DCH, the red LED is lit.)
To test all PRIs, enter:
LD 60
DISL loop
SLFT loop
The response is:
SLFT OK.
To enable all configured PRIs, enter:
LD 60
ENLL loop
The PRI loop is now up, the remote alarm is cleared, and the
D-channel is disabled.
To enable the NTBK51AA DDCH daughterboard, enter:
LD 96
ENL MSDL sl s c
The DDCH card is downloaded and enabled. The D-channel is
disabled.
To enable the D-channels, enter:
LD 96
ENL DCH X
If the D-channel is established, the response is:
DCH EST time and date
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
124), the PRI shown is disabled.