Nortel Media Gateway 1000E PRI Installation And Comissioning Manual page 91

Hide thumbs Also See for Media Gateway 1000E PRI:
Table of Contents

Advertisement

Procedure 25
Configuring the PRI2 loop timers using LD 73
Step
1
2
3
4
5
6
Table 23
PRI2 loop timers and thresholds (LD 73)
Prompt
Response
REQ
aaa
TYPE
PRI2
FEAT
LPTI
LOOP
loop
MFF
aaa
ACRC
(NO) YES
ALRM
aaa
RAIE
(NO) YES
mc mt oc ot
SLP
...
...
OSG1
nnnM
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
Action
Log on to the CS 1000E.
Enter the command:
LOGI
System response:
USERID?
Enter the default username:
admin1 or admin2
System response:
PASS?
Enter the default password:
0000
Access LD 73. Enter the command:
LD 73
Enter the responses shown in
thresholds (LD 73)" (page
Description
Request (aaa = CHG, END, NEW, OUT, or PRT).
DTI2 and JDMI are not supported for the PRI Gateway.
Feature = SYTI (System Timers).
Loop number for PRI2.
Multiframe format (aaa = AFF or CRC).
Automatic reporting of CRC-4 error.
Default alarm handler selected (aaa = REG or ALT).
RAIE Group II alarm state enabled or disabled.
Slip count.
Out-of-Service Guard time Group 1.
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
Configure E1/T1 ports on a Call Server 91
Table 23 "PRI2 loop timers and
91).