Nortel Media Gateway 1000E PRI Installation And Comissioning Manual page 100

Hide thumbs Also See for Media Gateway 1000E PRI:
Table of Contents

Advertisement

100 Configure an E1/T1 card
Procedure 32
Enabling the NTAK93AB daughterboard
Step
1
2
3
4
Procedure 33
Enabling the clock controller
Step
1
2
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
If the D-channel is established and operational, the system responds
with DCH x EST in LD 96.
Action
In LD 75, enter the command to enable all PRI loops:
ENL DDCS 1
Enter the command to enable the DCHI where the DCHI is enabled,
but all channels are disabled:
ENL DDSL n
To enable the D-Channels, enter this command:
STRT n
To request the current status of the D-channel, enter the command:
STAT DDSL
If the D-channel is operational and enabled, the response is ENBL
ACTIVE. All configured channels are normally enabled.
Action
In LD 60, enter the command to enable the system clock controller
on the specific superloop and shelf:
ENL CC1s
Enter the command to enable clock tracking on the Gateway
specified by the superloop and shelf tracking to primary, secondary
or free run:
TRCK aaa 1 s
where aaa is:
PCK for the primary track clock
SCLK is the track secondary clock
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
—End—
—End—