SLFT loop
Invoke hardware self-test on loop.
SLFT l ch
Invoke partial hardware self-test on channel ch.
LCNT (loop)
List contents of alarm counters on one or all DTI/PRI loops
RLBK loop
Close loop at carrier interface point of testing. (The card must be disabled.)
RLBK loop ch
Close channel ch at carrier interface point. (The channel must be disabled.)
STAT
Get status of all loops.
STAT loop
Get status of DTI/PRI loop
STAT loop ch
Get status of channel
DLBK loop
Disable remote loop back test
DLBK l ch
Disable remote loop back test.
RCNT
Reset alarm counters of all DTi/PRI loops.
RCNT loop
Reset alarm counter of DTI/PRI loop.
RMST loop
Perform self-test on loop.
RMST l ch
Perform self-test on specified channel (2.0 Mb/s DTI/PRI only.)
To maintain the clock controller, follow
controller using LD 60" (page
Procedure 47
Maintaining the clock controller using LD 60
Step
1
2
3
4
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
Action
Log on to the CS 1000E.
Enter the command:
LOGI
System response:
USERID?
Enter the default username:
admin1 or admin2
System response:
PASS?
Enter the default password:
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
Maintain PRI digital trunk loops 121
—End—
Procedure 47 "Maintaining the clock
121).