78 Configure an E1/T1 card
DLOP
loop dd ff
MG_CARD
supl sh card
MODE
PRI
TMDI
NO
...
...
YALM
FDL, DG2
TRSH
0 - 15
...
...
Procedure 17 "Configuring PRI2 loops using LD 17" (page 78)
the configuration in LD 17 to support PRI2/E1 loops (common equipment
parameters) on the PRI Gateway.
Procedure 17
Configuring PRI2 loops using LD 17
Step
1
2
3
4
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
Digital loop (1.5 Mb)
The format is: loop is 0–255, dd is 0-24 (maximum
simultaneous calls) and ff is D2, D3, D4, or ESF.
Enter X to delete the loop.
The physical card for the digital loop association to the PRI
Gateway is required.
The format is: superloop, shelf num, card num. For the PRI
Gateway, card 1-8 is applicable.
Mode of operation.
TMDI functionality is not supported for MGP gateway.
Yellow alarm method.
Threshold.
Action
Log on to the CS 1000E.
Enter the command:
LOGI
System response:
USERID?
Enter the default username:
admin1 or admin2
System response:
PASS?
Enter the default password:
0000
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
—End—