Qfx10002 Dc Power Cable Specifications - Juniper QFX10002 Hardware Manual

Hide thumbs Also See for QFX10002:
Table of Contents

Advertisement

Table 25: DC Power Specifications for a QFX10002
Item
DC input voltage
DC input current rating
Typical power consumption
Maximum power consumption
We recommend that the 48 VDC facility DC source be equipped with a circuit breaker rated at 40 A (–
48 VDC) minimum, or as required by local code.

QFX10002 DC Power Cable Specifications

QFX10002 DC power supplies require a D-Sub 3W3-type connector. The three pins on the connector
provide –48 VDC input (–), return (+), and ground connections to the power supply.
NOTE: The optional right-angle DC power cables, CBL-JNP-PWR-DSUB2 and CBL-JNP-PWR-
DSUB3, do not include a ground connection wire. See
on page
105.
Specifications
Rated operating voltage: VDC -48 VDC to -60 VDC
Operating voltage range: –40 VDC through -72 VDC
40 A maximum for QFX10002-36Q and QFX10002-72Q
57.5 A maximum for QFX10002-60C
1050 W for QFX10002-72Q
1642 W for QFX10002-60C
560 W for QFX10002-36Q
1425 W for QFX10002-72Q
1857 W for QFX10002-60C
800 W for QFX10002-36Q
"Connecting the QFX10002 to Ground"
58

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qfx10002-36qQfx10002-60cQfx10002-72q

Table of Contents