IMA Programming Model
34.4.5.2.1 IMA Link Receive Control (ILRCNTL)
The fields of the ILRCNTL register are shown in Figure 34-24
0
Field
GA
8
Field Add_new
Figure 34-24. IMA Link Receive Control (ILRCNTL)
Table 34-20 describes the ILRCNTL bit fields.
Bits
Name
0
GA
Group assigned flag. Set by software after group parameters have been validated.
0 Group unassigned.
1 Group assigned.
1
SES
Severely errored seconds. Set by software when a severely errored second indication is
detected. When set, causes the receive stuff event counter and ICP violation counter to stop
counting.
2
TRL
Identifies this link in the group as the Timing Reference Link (NOTE: Only one link per group
can be selected as the TRL).
3-4
RXSC
Receive status/control. Sets the receive mode of the IMA link.
00Filler mode. The IMA link processes only ICP cells. Data cells are replaced with filler cells.
01Active mode. The IMA link is capable of receiving data cells.
10Dropped. Must be set by the user during the process of dropping the link. Dropped links are
treated filler mode until they are switched out of the receive round-robin (i.e. data cells are
replaced with filler cells).
11Reserved.
5-7
IGNUM
Determines to which IMA group this link belongs. Contains the number of the link's associated
IMA Group Table entry.
Note: This value need not be the same as the group's IMA ID; the IMA ID is programmed
separately in the receive group's RIMAID field.
8
ADD_NEW
Identifies this link as a new/added link to a group. Software must flip (0 to 1 or 1 to 0) this bit
ONLY when adding a link to an existing group that is operational. If ADD_NEW =
ILRSTATE[ADD_NEW_M] = 0, set ADD_NEW to 1 to indicate this is an added link. If
ADD_NEW = ILRSTATE[ADD_NEW_M] = 1, set ADD_NEW to 0 to indicate this is an added
link. Initialize to zero.
9
MON_ICP
Setting this bit will allow changed ICP cells received on this link to be passed on to the ATM
layer (defined channel). The user must monitor at least one link in order for ICP cells to be
passed on to the ATM layer.
10 - 15 —
Reserved, initialize to zero.
34.4.5.2.2 IMA Link Receive State (ILRSTATE)
The fields of the ILRSTATE register are shown in Figure 34-25
34-44
Freescale Semiconductor, Inc.
1
2
SES
TRL
9
10
MON_ICP
Table 34-20. ILRCNTL Field Descriptions
MPC8280 PowerQUICC II Family Reference Manual
For More Information On This Product,
Go to: www.freescale.com
3
4
5
RXSC
Description
7
IGNUM
15
MOTOROLA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerquicc ii mpc8270Powerquicc ii mpc8275Powerquicc ii mpc8280

Table of Contents