Omron CompoNet MX2 Series User Manual page 103

Inverter, communications unit
Hide thumbs Also See for CompoNet MX2 Series:
Table of Contents

Advertisement

Name
Drive Status Detail
Rotation Speed Monitor
Output Current Monitor
Trip Cause
CompoNet Communications Unit User's Manual (I582-E1)
0: Stopping
1: Running
2: Jogging
3: Free running
4: Direct current DC braking
5: Restart (Retry)/Error detection (Deceleration stop)
7: Restart (Retry) in process
8: Waiting for restart (retry)
10: Fault/Trip
11: Undervoltage condition
If parameter P049 (Number of Poles for Rotation Speed Setting) is set appropri-
ately, the rotational speed unit is [min
If parameter P049 (Number of Poles for Rotation Speed Setting) is set to 0, the
frequency is monitored in units of [0.01 Hz].
Unit: [0.1 A]
Displays direct trip cause. Decimal values 1 to 99 correspond to trips E01 to
E99.