3 Network Startup
Frequency Reference/RUN Command Settings
Inverter parameters A001 and A002 set Frequency reference selection and RUN command selection.
When P046 is set to 2 (Extended Speed and Torque Control), 4 (Extended Control I/O), or 5 (Extended
Control I/O and Multi function I/O Monitor), set these parameters according to the following table.
 Destination Selection Parameter Settings
Parameter
A001
A002
 Destination Selection Parameter Settings
Parameter
A001
A002
Precautions for Correct Use
Precautions for Correct Use
To switch the Control Method using the REF (Net.Ref.) or CTR (Net.Ctrl.) bit signal, set as fol-
lows.
CTR
REF
• Set the Control Method to which you want to switch in parameter A001/A002.
Torque Control Settings
To use torque control, configure the parameters related to torque control according to the
MX2/RX-series Inverter User's Manual.
Configure the torque control parameters as follows if you want to use the Torque Reference or Torque
Bias Mode on CompoNet Remote I/O.
 Torque Control Parameter Settings
Parameter
P033
P036
 Torque Control Parameter Settings
Parameter
P033
P036
3 - 8
Description
1st Frequency Reference Selection
1st RUN Command Selection
Description
1st Frequency Reference Selection
1st RUN Command Selection
Bit
Name
Net.Ctrl.
Net.Ref.
Description
Torque Reference Input Selection
Torque Bias Mode
Description
Torque Reference Input Selection
Torque Bias Mode
04: Option
05: Option 2
Description
0: Follow the setting of parameter A002.
1: Follow the reference from network.
0: Follow the setting of parameter A001.
1: Follow the reference from network.
06: Option
05: Option
07: Option 2
06: Option 2
CompoNet Communications Unit User's Manual (I582-E1)
Setting
Setting
Setting
Setting