Omron CompoNet MX2 Series User Manual page 102

Inverter, communications unit
Hide thumbs Also See for CompoNet MX2 Series:
Table of Contents

Advertisement

4 Remote I/O
Precautions for Safe Use
For safety reasons, the FW, RV, and RS command must be output after the cause of fault/trip
is removed.
Extended Speed and Acceleration Control
Assembly ID: 111 Dec (6F hex)
 Input Format (CS/CJ-series ← Inverter)
Word
Byte
No.
No.
n
0
1
n + 1
2
3
n + 2
4
5
n + 3
6
7
 Input Bit/Data Details
Name
FWR
During forward
operation
RVR
During reverse
operation
AL
Alarm output
FA1
Constant speed
reached
MI1 to
Multi-function Input
MI7
Monitor
MI8
Multi-function Input
Monitor
CFN
Ctrl. from Net
RFN
Ref. from Net
FWT
Forward Rotation
Terminal Input
Monitor
4 - 8
bit 7
bit 6
bit 5
MI3
MI2
MI1
Rotation Speed Monitor (Low byte)
Rotation Speed Monitor (High byte)
Output Current Monitor (Low byte)
Output Current Monitor (High byte)
RFN
CFN
FWT
0: During reverse run/Stopping
1: During forward run
0: During forward run/Stopping
1: During reverse run
0: Normal
1: Fault/Trip
0: Accelerating or decelerating
1: Frequency agree
Monitors multi function inputs S1 to S7
0: OFF
1: ON
Monitors multi function inputs S8
0: OFF
1: ON
0: Rotation Speed Reference follows the setting of parameter A001; Accelera-
tion/Deceleration Time follows the setting of parameter F002/F003.
1: CompoNet reference
0: Follow the setting of parameter A001.
1: CompoNet reference
Monitors the forward rotation command terminal state.
0: OFF
1: ON
Bit Allocation
bit 4
bit 3
bit 2
FA1
AL
Drive Status Detail
Trip Cause
MI8
MI7
MI6
Description