A-2-2

Control Supervisor Object (Class 29 hex)

Supported Service Codes
Table A-19 Control Supervisor Object - Supported Service Codes
Service Code No. (hex)
0E
10
Object Details
Table A-20 Control Supervisor Object - Object Details
Instance
Attribute
(hex)
(hex)
01
03
04
05
06
07
08
09
0A
0B
0C
0D
Additional Information
The comparison between the inverter Error/Trip codes and the CIP Fault/Warning codes is
shown in Table A-20.
A - 12
Reads Attribute data.
Writes Attribute data.
Name
Description
Forward/
0: Stop
Stop
1: Forward
Reverse/
0: Stop
Stop
1: Reverse
Net Control
0: Follow the setting of param-
eter A002.
1: CompoNet reference
State
Drive status
During For-
0: Stop
ward Run
1: During forward run
During
0: Stop
Reverse
1: During reverse run
Run
Inverter
0: Not ready
Ready
1: Ready
Fault
0: Normal
1: Fault
Alarm
0: Normal
1: Alarm
Fault Reset
Resets the Fault/Trip state of
the inverter when 1 is written.
Fault Code
Fault/Trip state code
Service Description
Setting
Default
Range
----
0
----
0
----
0
----
----
----
----
----
----
----
----
----
----
----
----
----
0
----
----
CompoNet Communications Unit User's Manual (I582-E1)
Read Write
Size
Yes
Yes
BOOL
Yes
Yes
BOOL
Yes
Yes
BOOL
Yes
No
UINT
Yes
No
BOOL
Yes
No
BOOL
Yes
No
UINT
Yes
No
BOOL
Yes
No
BOOL
Yes
Yes
BOOL
Yes
No
UINT