30 Testing and adjusting
4.
Loosen bolts (2), then rotate the cleaner plate
as shown in the diagram.
5.
Raise the cleaner 5 mm.
6.
Tighten nuts (5) and (6).
BR380JG-1E0
7.
Rotate cleaner shaft (8) so that cleaner plate
(4) is at right angles.
8.
Check that cleaner tip (7) and the belt are at
the 60° position, then tighten bolt (2) and nut
(1).
If the angle of the tip of the cleaner and the belt
is less than 60°, move the cleaner up.
3
Bolt M12: 34.3 Nm {3.5 kgm}
SEN02305-01
41