SEN01352-00
4.
When there is abnormally high pressure.
When pressure (PR) of the self pressure
q
reducing valve becomes abnormally high, ball
(10) pushes against the force of spring (9),
separates from the seat, and allows hydraulic
oil to flow from output port (PR) o (T), so pres-
sure (PR) goes down. This action protects the
equipment at the destination for the hydraulic
pressure supply (PPC valve, electromagnetic
valve, etc.) from abnormally high pressure.
(See Fig. 4)
14
10 Structure, function and maintenance standard
BR380JG-1E0