10 Structure, function and maintenance standard
If an abnormal load is applied and a red lamp
q
lights up (See the table on the next page),
depress return switch (9) or restart the abnor-
mally loaded work equipment, and the lamp is
reset.
Conditions for lighting work equipment lamp
Conveyor
White lamp
Stop
lights up
White lamp
Forward drive
lights up
Reverse drive
—
Overload
—
Red lamp
Abnormal load
lights up
Stopped under
—
overload
1. An overload on the crusher means that an excessive pressure load is applied to the crusher.
*
2. An abnormal load on the crusher means that the crusher lock cylinder slips in the clearance increasing
*
direction or the swing tooth moves into the maximum crusher clearance range.
3. A red lamp lighting because of an abnormal load is reset when "return" switch (9) is depressed or the
*
abnormally loaded work equipment is restarted.
BR380JG-1E0
Crusher
Feeder
White lamp
White lamp
lights up
lights up
White lamp
White lamp
lights up
lights up
White lamp
—
lights up
Red lamp
—
flashes (*1)
Red lamp
lights up
—
(*2, 3)
Green lamp
—
flashes
Side con-
Magnetic
veyor
separator
(If equipped)
Transparent
Transparent
Transparent
Transparent
—
—
—
—
Red lamp
Red lamp
lights up
lights up
—
—
SEN01355-00
Secondary
Vibratory
conveyor
screen
(If equipped)
(If equipped)
Transparent
Transparent
Transparent
Transparent
—
—
—
—
Red lamp
Red lamp
lights up
lights up
—
—
43