30 Testing and adjusting
29. Function for crusher clearance record [10]
The machine monitor records the information
about the crusher clearance setting.
The machine monitor records the informa-
q
tion up to 10 times. After recording 10
times, the machine monitor discards the
data in order from the oldest one and
keeps the newest ones.
When the mode selector switch is changed
q
from the "testing mode" to "another mode",
if the crusher clearance saved previous
time is different from the current crusher
clearance, the machine monitor saves the
current crusher clearance.
1)
Selection of menu
Select "10 Crusher Clearance Record" in
the initial display of Service Menu, and
depress [
] switch.
2)
Information shown in display
1]
Crusher clearance
2]
Service meter reading at which
crusher clearance was saved
BR380JG-1E0
30. Function for lock cylinder slip record [11]
The machine monitor records the information
about the past slip of the crusher lock cylinder
(service meter reading).
The machine monitor records the slips up
q
to 10 times. After recording 10 times, the
machine monitor discards the data in
order from the oldest one and keeps the
newest ones.
The total number of the recorded slips
q
above 10 is counted and recorded up to
999.
1)
Selection of menu
Select "11 Lock Cylinder Slip Record" in
the initial display of Service Menu, and
depress [
] switch.
SEN02304-00