SEN02304-00
21. Function of abnormality record [02]
The machine monitor records and classifies
the past failure information as into the electri-
cal and mechanical failures. It allows display-
ing and checking the information through the
following operations.
1)
Menu selection
Select "02 Abnormality Record" in the ini-
tial display of Service Menu and depress
[ ] switch.
2)
Sub menu selection
Select the sub menu from the abnormality
record menu screen and then press [ ]
switch.
Number
Sub menu of abnormality record
00
Return (End of abnormality record)
01
Electrical systems
02
Mechanical systems
20
30 Testing and adjusting
3)
Contents of display of electrical system
abnormality record information screen
(1): Occurrence order of abnormalities
f r o m l a t e s t o n e / To ta l n u m b e r o f
records
(2): Failure code (Equipment: 4 digits,
Phenomena: 2 digits)
(3): Elapsed time on service meter from
the first occurrence
(4): Contents of trouble
a See the operator menu "Failure
codes table".
4)
Contents of display of mechanical system
abnormality record information screen
(1): Record number
(2): Contents of trouble
(3): Failure code (Equipment: 4 digits,
Pheomena: 2 digits)
(4): Total number of occurrences
(5): Service meter reading at first occur-
rence
a See the operator menu "Failure
codes table".
BR380JG-1E0