11. TROUBLESHOOTING

11.4 When alarm or warning has occurred

11.4.1 Alarms and warning list

When a fault occurs during operation, the corresponding alarm or warning is displayed. If any alarm or warning
has occurred, refer to section 11.4.2 or 11.4.3 and take the appropriate action. When an alarm occurs, ALM
turns off.
After its cause has been removed, the alarm can be deactivated in any of the methods marked
deactivation column.
Display
A10
Undervoltage
A12
Memory error 1 (RAM)
A13
Clock error
Memory error 2
A15
(EEP-ROM)
Encoder error 1
A16
(At power on)
A17
Board error
Memory error 3
A19
(Flash-ROM)
A1A
Motor combination error
A20
Encoder error 2
A24
Main circuit error
A25
Absolute position erase
A30
Regenerative error
A31
Overspeed
A32
Overcurrent
A33
Overvoltage
A35
Command pulse frequency alarm
A37
Parameter error
A45
Main circuit device overheat
A46
Servo motor overheat
A47
Cooling fan alarm
A50
Overload 1
A51
Overload 2
A52
Error excessive
A61
Operation alarm
A8A
Serial communication time-out
A8D
CC-Link alarm
A8E
Serial communication error
888
Watchdog
Note 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.
2. Turns on RY(n+1)A or RY(n+3)A.
3. Clicking the "Alarm reset" button on the "Alarm display" screen of MR Configurator allows an alarm to be deactivated.
Pressing the "STOP RESET" key of the parameter unit allows an alarm to be deactivated.
POINT
Configure up a circuit which will detect the trouble (ALM) signal and turn off the
servo-on (RYn0) at occurrence of an alarm.
Name
Power
OFF ON
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
Alarm deactivation
(Note3)
(Note2)
MR
Alarm
Configurator
reset
parameter
(RES)
unit
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
11 - 3
Display
Name
Home positioning incomplete
A90
warning
A92
Open battery cable warning
A96
Home position setting error
A98
Software limit warning
A99
Stroke limit warning
A9D
CC-Link warning 1
A9E
CC-Link warning 2
A9F
Battery warning
AE0
Excessive regeneration warning
AE1
Overload warning 1
AE3
Absolute position counter warning
AE6
Servo emergency stop warning
Cooling fan speed reduction
AE8
warning
AE9
Main circuit off warning
AEC
Overload warning 2
AED
Output watt excess warning
in the alarm