External Appearance And Key Explanations - Mitsubishi Electric MELSERVO-J3 Series Manual

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

8. PARAMETER UNIT (MR-PRU03)

8.1 External appearance and key explanations

This section gives the external appearance and explanations of the keys.
Display
LCD (16 characters x 4 lines)
Used to display the following or others:
Parameter setting
Monitor
ALM/
DATA
MON
DGN
PARAM
Fn
ESC
SHIFT
D
7
E
8
F
9
4
6
A
B
5
C
1
2
3
0
1STEP
Key
MON
ALM/
DGN
DATA
PARAM
TEST
PRU03
Fn
SHIFT
TEST
ESC
FWD
REV
STOP
RESET
FWD
REV
STOP
RESET
0
to
9
F
1STEP
Monitor mode key
Used to display the monitor screen.
Alarm/diagnosis mode
Used to display the alarm/DO forced output/diagnosis selection
screen.
Parameter mode key
Used to display parameter selection screen.
Press this key while holding down the "SHIFT" key to display the
point table setting screen.
Test operation mode key
Used to display the exit/JOG operation/positioning operation/motor-
less operation/DO forced output/single-step feed selection screen.
Function key
Used to perform various operations in the test operation mode.
Used to display the parameter range and point table setting range.
SHIFT key
Used to enter hexadecimal values. Press the "4" to "9" keys while
holding down the "SHIFT" key to enter A to F.
Press the "
" keys while holding down the "SHIFT" key to move
to the previous or next screen.
ESC key
Used to display the screen at one step upper hierarchical level. (not
the pervious screen)
Used to display the setting selection screen (the initial screen) of the
monitor mode.
Scroll key
Used to move the cursor across the screen or scroll the screen.
Press this key while holding down the "SHIFT" key to move to the
previous or next screen.
Used to change parameter No. or point table No.
Forward rotation key
Used to start the forward rotation in the test operation mode (JOG
operation/positioning operation).
Symbol key/reverse rotation key
Used to start the reverse rotation in the test operation mode (JOG
operation/positioning operation).
Used together with the "SHIFT" key to enter negative values. To exit
the negative value entry mode, press the "SHIFT" key again and
press the "-" key. ("-" disappears.)
Stop/reset key
Used to stop temporarily in the JOG operation/positioning
operation/single-step feed.
The "RESET" key is valid when the "Fn" key is not pressed (i.e. at a
stop).
Used to reset alarms or alarm history, or clear cumulated monitor
data or inputs.
Normal operation cannot be stopped with this key.
Enter key
Used to determine the selection, numerical values, etc.
Used to determine to exit the test operation mode, or enter the
motor-less operation.
Used to switch ON/OFF in the DO output screen.
Numerical keys
Used to enter parameter No., setting values, etc.
Press the "4" to "9" keys while holding down the "SHIFT" key to enter
A to F.
Decimal point key
Used to enter a decimal point.
Used to start the single-step feed.
8 - 2
Key explanations

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents