2. INSTALLATION
(b) Installation of two or more servo amplifiers
Leave a large clearance between the top of the servo amplifier and the internal surface of the control
box, and install a cooling fan to prevent the internal temperature of the control box from exceeding the
environmental conditions.
When installing the servo amplifiers closely, leave a clearance of 1mm between the adjacent servo
amplifiers in consideration of mounting tolerances.
In this case, bring the ambient temperature within 0 to 45
effective load ratio.
Control box
100mm
or more
30mm
or more
Leaving clearance
(2) 11k to 22kW
(a) Installation of one servo amplifier
10mm
or more
POINT
Close mounting is available for the servo amplifier of under 3.5kW for 200V
class and 400W for 100V class.
10mm
or more
30mm
or more
40mm or more
Control box
40mm or more
Servo amplifier
120mm
or more
(32 to 113 ), or use it at 75% or a smaller
Control box
1mm
30mm
or more
40mm or more
Mounting closely
Control box
Wiring allowance
80mm
10mm
or more
2 - 2
100mm
or more
1mm
30mm
or more
Top
Bottom
Top
Bottom