6. PARAMETERS

6.3.6 Software limit

A limit stop using a software limit (parameter No.PC31 to PC34) is made as in stroke end operation. When a
motion goes beyond the setting range, the motor is stopped and servo-locked. This function is made valid at
power-on but made invalid during home position return. This function is made invalid when the software limit
setting is the same as the software limit
setting. A parameter error (A37) will occur if the software limit
setting is less than the software limit
setting.
Inhibited area
Movable area
Movable
Unmovable
Current position
Software limit
6 - 28