5. OPERATION
(2) Indication list
Indication
b # # Waiting for CC-Link
communication
(Note 1) d # # Ready
(Note 1) C # # Not ready
(Note 2) $ $ $ Ready for operation
(Note 3) A
Alarm Warning
8
8 8
CPU error
b
0 0.
(Note 4)
(Note 4)
d
# #.
Test operation mode
(Note 1)
C
# #.
Note 1. ## denotes any of numerals 00 to 16 and what it means is listed below.
Note 2. $$$ indicates numbers from 0 to 255, and the number indicates the executing point table number.
3.
indicates the warning/alarm No.
4. Requires MR Configurator or MR-PRU03 parameter module.
Status
Power of the CC-Link master module was switched on at the condition that the power of
CC-Link master module is OFF.
The CC-Link master module is faulty.
The servo was switched on after completion of initialization and the servo amplifier is ready
to operate. (This is indicated for 2 seconds.)
The servo amplifier is being initialized or an alarm has occurred.
Two seconds have passed after the servo amplifier is ready to operate by turning ON the
servo-on (RYn1).
The alarm No./warning No. that occurred is displayed. (Refer to section 11.4.)
CPU watchdog error has occurred.
JOG operation positioning operation programmed operation DO forced output single-
step feed
Motor-less operation
##
00
01
02
03
:
:
62
63
64
Description
Description
Set to the test operation mode.
Station number 1
Station number 2
Station number 3
:
:
Station number 62
Station number 63
Station number 64
5 - 9

Advertisement

Table of Contents

Troubleshooting