6. PARAMETERS
(2) Auto tuning response (parameter No.PA09)
If the machine hunts or generates large gear sound, decrease the set value. To improve performance, e.g.
shorten the settling time, increase the set value.
Setting
Response
1
Low response
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Middle response

6.1.10 In-position range

No.
Symbol
PA10
INP
In-position range
Set the range, where In position (RXn1) and Movement completion (RXnC) are output, in the command pulse
unit before calculation of the electronic gear. With the setting of parameter No.PC24, the range can be
changed to the encoder output pulse unit.
Command pulse
Droop pulse
In position (RXn1)
Guideline for machine
resonance frequency [Hz]
10.0
11.3
12.7
14.3
16.1
18.1
20.4
23.0
25.9
29.2
32.9
37.0
41.7
47.0
52.9
59.6
Parameter
Name
Command pulse
ON
OFF
Setting
Response
17
Low response
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Middle response
Servo motor Droop pulse
In-position range [ m]
6 - 8
Guideline for machine
resonance frequency [Hz]
67.1
75.6
85.2
95.9
108.0
121.7
137.1
154.4
173.9
195.9
220.6
248.5
279.9
315.3
355.1
400.0
Initial
Unit
Setting range
value
100
m
0 to 10000