5. OPERATION
(3) Manual pulse generator multiplication
(a) Using the parameter for setting
Use parameter No.PA05 to set the multiplication ratio of the servo motor rotation to the manual pulse
generator rotation.
Parameter No.PA05 setting
0
1
2
(b) Using the input signals for setting (devices)
Set the pulse generator multiplication 1 (TP0) and the pulse generator multiplication 2 (TP1) to the CN6
connector pins in the parameters of Nos. PD06 to PD08.
(Note)
Pulse generator multiplication 2
(TP1)
0
0
1
1
Note. 0: OFF
1: ON
(4) Operation
Turn the manual pulse generator to rotate the servo motor. For the rotation direction of servo motor, refer to
(2) in this section.
Multiplication ratio of servo motor rotation to
manual pulse generator rotation
1 time
10 times
100 times
(Note)
Pulse generator multiplication 1
(TP0)
0
1
0
1
5 - 30
Multiplication ratio of servo motor rotation
to manual pulse generator rotation
Parameter No.PA05 setting valid
1 time
10 times
100 times
Moving distance
1[ m]
10[ m]
100[ m]
Moving distance
1[ m]
10[ m]
100[ m]