Data Communication Timing Charts; Monitor Codes - Mitsubishi Electric MELSERVO-J3 Series Manual

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

3. CC-LINK COMMUNICATION FUNCTIONS

3.6 Data communication timing charts

3.6.1 Monitor codes

(1) When 1 station is occupied
Monitor 1
(RWwn)
Monitor 2
(RWwn+1)
ON
Monitor execution
demand (RYn8)
OFF
ON
Monitoring
(RXn8)
OFF
Monitor 1 data
(RWrn)
Monitor 2 data
(RWrn+1)
Respond code
(RWrn+2)
Set the monitor codes (refer to section 3.5.3) to Monitor 1 (RWwn) and Monitor 2 (RWwn+1) and turn Monitor
output execution demand (RYn8) to ON. Turning Monitor execution demand (RYn8) to ON sets the next data.
Data are all hexadecimal numbers. At this time, Monitoring (RXn8) turns to ON at the same time.
Monitor data 1 (RWrn): Data demanded by Monitor 1 (RWwn)
Monitor data 2 (RWrn+1): Data demanded by Monitor 2 (RWwn+1)
For 32-bit data, set the lower 16 bits of the monitor code to Monitor 1 (RWwn) and the upper 16 bits to Monitor
2 (RWwn+1) and read them simultaneously.
The monitor data set to the remote register are always updated while Monitor execution demand (RYn8) is ON.
When Monitoring (RXn8) turns to OFF, the data set to Monitor data RWrn, RWrn+1 are held. If the monitor
code not in the specifications is set to either Monitor 1 (RWwn) or Monitor 2 (RWwn+1), the corresponding
error code (
1) is set to respond code.
3 - 34
Data HOLD

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents