14. OPTIONS AND AUXILIARY EQUIPMENT
(3) Parameter setting
Set parameter No.PA02 according to the option to be used.
Parameter No.PA02
0 0
Regenerative resistor, regenerative option
Standard supplied regenerative resistor
Standard supplied regenerative resistor
(with a cooling fan to cool it)
MR-RB5E
MR-RB5E (with a cooling fan to cool it)
MR-RB9P
MR-RB9P (with a cooling fan to cool it)
MR-RB9F
MR-RB9F (with a cooling fan to cool it)
MR-RB6B-4
MR-RB6B-4 (with a cooling fan to cool it)
MR-RB60-4
MR-RB60-4 (with a cooling fan to cool it)
MR-RB6K-4
MR-RB6K-4 (with a cooling fan to cool it)
(4) Connection of the regenerative option
The regenerative option will cause a temperature rise of
examine heat dissipation, installation position, used cables, etc. before installing the option. For wiring, use
flame-resistant cables and keep them clear of the regenerative option body. Always use twisted cables of
max. 5m length for connection with the servo amplifier.
Selection of regenerative option
00: Regenerative option is not used
For servo amplifier of 100W, regenerative resistor is not used.
For servo amplifier of 200 to 7kW, built-in regenerative resistor is used.
Supplied regenerative resistors or regenerative option is used with
the servo amplifier of 11k to 22kW.
01: FR-BU2-(H) FR-RC-(H) FR-CV-(H)
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50(Cooling fan is required)
08: MR-RB31
09: MR-RB51(Cooling fan is required)
80: MR-RB1H-4
81: MR-RB3M-4(Cooling fan is required)
82: MR-RB3G-4(Cooling fan is required)
83: MR-RB5G-4(Cooling fan is required)
84: MR-RB34-4(Cooling fan is required)
85: MR-RB54-4(Cooling fan is required)
FA: When the supplied regenerative resistor is cooled by the cooling
fan to increase the ability with the servo amplifier of 11k to 22kW.
Setting
value
POINT
When the MR-RB50 MR-RB51 MR-RB3M-4 MR-RB3G-4 MR-RB5G-4
MR-RB34-4 MR-RB54-4 is used, a cooling fan is required to cool it. The
cooling fan should be prepared by the customer.
For the sizes of wires used for wiring, refer to section 14.9.
00
FA
00
FA
00
FA
00
FA
00
FA
00
FA
00
FA
100
relative to the ambient temperature. Fully
14 - 22