In-Position Range - Mitsubishi Electric Melservo-J3 Series MR-J3-B Instruction Manual

Melservo j3 series general-purpose ac servo sscnet compatible
Hide thumbs Also See for Melservo-J3 Series MR-J3-B:
Table of Contents

Advertisement

5. PARAMETERS
(2) Auto tuning response (parameter No. PA09)
If the machine hunts or generates large gear sound, decrease the set value. To improve performance, e.g.
shorten the settling time, increase the set value.
Setting
Response
1
Low response
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Middle response

5.1.7 In-position range

No.
Symbol
PA10
INP
In-position range
Set the range, where ln position (INP) is output, in the command pulse unit.
Command pulse
Droop pulse
In position (INP)
Guideline for Machine
Resonance Frequency [Hz]
10.0
11.3
12.7
14.3
16.1
18.1
20.4
23.0
25.9
29.2
32.9
37.0
41.7
47.0
52.9
59.6
Parameter
Name
POINT
This parameter cannot be used in the speed control mode.
Command pulse
ON
OFF
Setting
Response
17
Low response
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Middle response
Initial Value
Servo motor droop pulse
In-position range [pulse]
5 - 6
Guideline for Machine
Resonance Frequency [Hz]
67.1
75.6
85.2
95.9
108.0
121.7
137.1
154.4
173.9
195.9
220.6
248.5
279.9
315.3
355.1
400.0
Unit
100
pulse
Setting Range
0 to 65535

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents