PN: 1725-36038-001_N.docx
PROXY1_DOMAIN = 10.0.0.138
PROXY1_DOMAIN = axlx.engr.local
ProxyDomain can be omitted if a specific proxy domain name is not
defined at the proxy server. If omitted, the ProxyDomain defaults to
the IP address of the proxy server.
i
PROXYn_CALLID_PER_LINE controls sending of the same
Call-ID header field for registrations sent to a particular
registrar. If this is enabled we will send Call-ID headers
differently. This may be needed for Mitel 3300 Controller
software prior to Release 9. E.g.
PROXY1_CALLID_PER_LINE = enable
PROXYn_MAIL_ACCESS: Enter your Voice Mail System's
j
Pilot Number. This is the main voicemail dial number. E.g.
PROXY1_MAIL_ACCESS = 7999
PROXY1_MAIL_ACCESS = sip:7999@10.0.0.138
PROXY1_MAIL_ACCESS = 7999@10.0.0.138
PROXY1_MAIL_ACCESS = 7999
PROXYn Mail Subscr is the proxy for mail center notifications. It is
almost never required in current versions of Asterisk. If you are using
Asterisk (non-business edition) before v1.2, this is necessary only if
the user is not subscribed automatically at registration. E.g. (specific
for a line number:3001)
PROXY1_MAIL_SUBSCR = sip:3001@vmail.asterisk.com
k PROXYn_FAILOVERIP is required for ININ Redundancy.
This value is the secondary IP address of the ININ server. If
the primary server fails this address is needed to make the
calls. E.g.
PROXY1_FAILOVERIP = 172.24.144.136
Proxy settings can differ depending on your server. See the sample
.cfg file and Appendix B for additional explanations about configuring
multiple proxies and other proxy settings not found in the above list.
Configure Call Logs
Call logs provide the user with logs of the most-recently incoming,
answered and missed calls. When enabled, the handset will locally
story the 20 most recent numbers. If disabled, the handset will not log
any calls. If this setting is enabled, it may be overridden on the
handset but such a disable will not persist after a power cycle.
5. CALL_LOGGING: enable or disable this feature. E.g.
CALL_LOGGING = disable