SENSOR TRAYS

1. Open the Cover jam access [1].
2. Release the hooks from the bottom, then remove the SENSOR TRAYS [2].
3. Disconnect the connector [3].
* There are hooks on the short side (1 place) and the long side (2 places) on the sensor.
After releasing the hook on the short side, slide the sensor to the short side and remove it.
[ 3 ]
[ 1 ]
[ 2 ]