Unique Switch 08x : Miscellaneous
Unique Switch 080 :
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Default tab on scan read
screen
4
0
3
0
Factory use only
2
0
Factory use only
1
1
Factory use only
0
1
Factory use only
Unique Switch 081 :
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Put dial error on journal
0: No
1: Yes
4
0
Factory use only
3
1
Factory use only
2
0
Factory use only
1
1
Factory use only
0
0
Factory use only
Unique Switch 082 :
Initial
Switch
Setting
7
1
Factory use only
6
0
Import / Export all data at
mirroring
0: No
1: Yes
5
0
Factory use only
4
0
Factory use only
3
1
Factory use only
2
0
Factory use only
1
1
Factory use only
0
0
Check market information at
mirroring
0: Yes
1: No
Unique Switch 083 ~ 084 — Factory use only
Adjust
Set the tab which should be displayed when you
switch to scan read screen.
Switch 5 4
Adjust
Set this switch to "1" to add dial error to journal.
Adjust
Import / Export all data at mirroring
Use this switch only when the main control board
is replaced. You can import / export the whole
machine information to the new board.
Use this switch only to import machine data from
a different ROM version name. When you set this
switch to "1", you can import a machine data form a
different ROM version name at mirroring.
3-66
Usage/Comments
1 1
[Apps]
1 0
[PC/USB]
0 1
[e-mail]
0 0
[Faves] (default)