4. Select the desired parameter by pressing the box.
5. To navigate through the machine parameter settings:
• The bits are ranged from 7 (left) to 0 (right).
• Press [ ] or [ ] of the cursor key to move the cursor.
• Press <0> or <1> on the numeric keys, or [ ] or [ ], to change the bit value.
• Press [Enter] to save the setting of the displayed parameter and return to the machine parameter
edit screen.
• Press [Back] not to save the setting of the displayed parameter.
6. If you want to set other parameters, repeat step 3-5. Otherwise, proceed to step 7.
7. Press <Reset> to return the machine to ready screen.
You can confirm the initial setting of each parameter by the network switch list.
The network switch list will be printed by pressing [Parameter Print] in step 2.
Network switch 000~001: Factory use only
Network switch 002:
Initial
Switch
Setting
7
0
Maximum session times of
SMTP
6
0
5
0
4
0
3
0
2
0
1
0
0
0
Network switch 003:
Initial
Switch
Setting
7
0
Number of retry times for
archive transmission
6
0
5
0
4
0
3
1
2
1
1
1
0
1
Adjust
Set up the maximum session times.
The number between 1 to 32 are available.
00011111 32 times
00001001 10 times
00000001 2 times
00000000 1 time (default)
Adjust
Set up the retry times for archive transmission.
This setting is adopted for the following transmission
when an available destination is set.
• Transmission to a shared folder
• E-mail transmission
11111111 255 times
00001111
00000001
00000000
3-103
Usage/Comments
:
:
Usage/Comments
:
15 times (default)
:
1 time
No retry