Attribute 3 ‑ Individual Autodialer Setting
Initial
Switch
Setting
7
1
TTI clock type
0 : AM PM clock
1 : 24 hour clock
6
1
TTI calendar type
5
0
4
1
TTI transmit
0: No
1: Yes
3
0
ECM response time
0: 3 sec
1: 4.8 sec
2
0
ECM error retransmit time
0: 200 ms
1: 400 ms
1
0
Interval between DIS and DCS
0
0
Switch 1
Switch 0
Attribute 4 ‑ Individual Autodialer Setting
Initial
Switch
Setting
7
0
ANSam detection
0 : Yes
1 : No
6
0
V. 34 transmission
0 : Yes
1 : No
5
0
CSI / TSI / CIG transmit
0 : Yes
1 : No
4
0
ECM mode
0 : On
1 : Off
3
0
Retransmit automatically when
receiving RTN / PIN signals
0 : Yes
1 : No
2
1
Factory use only
1
0
Factory use only
0
0
Factory use only
Attribute 5 ‑ Individual Autodialer Setting
Adjust
NOTE
Turning TTI transmission
off may violate local or
federal regulations.)
0 ms 500 ms 1000 ms 1500 ms
0
0
1
0
1
0
Adjust
(Equivalent to Memory Switch 012)
Usage/Comments
bit
6 5
1 1
dd mm yyyy (default)
1 0
mm dd yyyy
0 1
yyyy/mm/dd
When set at "0", transmission of the TTI is disabled.
The TTI includes the followings:
• Sender name
• Sender's fax number
• Data & time, and number of pages
To set the individually transmission of them, see
Memory SW 016.
The time limit to receive the response signal for the
ECM post message.
The time limit before the ECM error is retransmitted.
1
1
(Equivalent to Memory Switch 013)
Usage/Comments
During the V8 handshake, if some noise disturbs the
handshake and an error occurs, set to "1".
Individual setting for V.34 transmission.
When set at "1", transmission of the CSI, TSI and
CIG signals are disabled.
Determines ECM mode. ECM mode reduces docu-
ment memory and may lengthen transmission and
reception times.
When set to "1", retransmission disables automati-
cally if receiving RTN / PIN signals.
(Equivalent to Memory Switch 014)