12.2 Adjusting the winder filling quantity
Proper setting
The winding process will stop automatically when the required filling
quantity of the bobbin is reached.
Fig. 64: Adjusting the winder filling quantity
(1) - Screw
To adjust the winder filling quantity:
1. Loosen the screw (1).
2. Move the winder lever (2):
3. Re-tighten the screw (1).
4. Check the winder filling quantity by carrying out a winding process and
Information
To keep the thread from overflowing on the bobbin, observe the following
setting tolerances:
• Bobbin Ø 32 mm: Ø 31 ± 0.5 mm
• Bobbin Ø 28 mm: Ø 27 ± 0.5 mm
78
①
②
• Filling quantity too low: Turn the winder lever (2) outward
• Filling quantity too high: Turn the winder lever (2) inward
correct the setting if necessary.
(2) - Winder lever
Service Instructions D868 M-TYPE DELTA - 00.0 - 06/2020
Winder