Troubleshooting
Code
9310
9320
9330
9340
9350
9351
9352
9360
9361
9362
9910
9911
Service Instructions D868 M-TYPE DELTA - 00.0 - 06/2020
Type
Meaning
Error
Tape feeder not connected
Error
Tape feeder in lowered
position
Information
Material thickness sensor not
connected
Error
Remaining thread monitor
not connected
Error
Upper machine head pcb is
not connected
Error
Lower machine head pcb is
not connected
Error
Left thread tension pcb is not
connected
Error
Edge guide pcb is not
connected
Error
Edge guide x-axis pcb is not
connected
Error
Edge guide y-axis pcb is not
connected
Warning
Sewing stop
Warning
Power down
Remedial action
• Check connection cables
• Perform a software update
• Replace the control of the
tape feeder
• Check connection cables
• Perform a software update
• Replace material
thickness sensor
• Check connection cables
• Perform a software update
• Replace remaining thread
monitor
• Check cable
• Perform a software update
• Replacing the PCB
• Check cable
• Perform a software update
• Replacing the PCB
• Check cable
• Perform a software update
• Replacing the PCB
• Check cable
• Perform a software update
• Replacing the PCB
• Check cable
• Perform a software update
• Replacing the PCB
• Check cable
• Perform a software update
• Replacing the PCB
• Check tilt sensor on
machine
• Check 24V
• Replace control
• The control is switched off
215