DURKOPP ADLER D868 Service Instructions Manual page 202

M-type delta
Table of Contents

Advertisement

Code
1004
1005
1006
1007
1008
1010
1011
1012
1054
1055
1060
1061
200
Type
Meaning
Error
Incorrect sewing motor
direction of rotation
Error
Motor blocked
Error
Maximum speed exceeded
Error
Error in the reference run
Error
Sewing motor encoder error
Error
External synchronizer plug
(Sub-D, 9-pin) not connected
Error
Encoder Z pulse missing
Error
Synchronizer fault
Error
Internal short circuit
Error
Sewing motor overload
Error
Sewing motor overload /
overvoltage /overcurrent
Error
Sewing motor overload /
overvoltage /overcurrent
Service Instructions D868 M-TYPE DELTA - 00.0 - 06/2020
Troubleshooting
Remedial action
• Replace encoder
• Check motor plug
assignment and change it
if necessary
• Check wiring in machine
distributor and change it, if
necessary
• Test motor phases and
check for correct value
• Check for stiff movement
• Replace encoder
• Replace sewing motor
• Replace encoder
• Perform reset
• Check class (t 51 04)
• Replace encoder
• Check for stiff movement
• Replace encoder
• Connect cable of external
synchronizer to control,
make sure that interface
(Sync) is correct
• Only recommended for
machines with
transmission!
• Switch off the control, use
handwheel to turn, and
switch on the control
again
• If error is not corrected,
check encoder
• Replace synchronizer
• Replace control
• Check for stiff movement
• Replace encoder
• Replace sewing motor
• Check selection of class
• Replace control
• Replace motor
• Replace encoder
• Check selection of class
• Replace control
• Replace motor
• Replace encoder

Advertisement

Table of Contents
loading

Table of Contents