Power Supply Unit (Psu); Safety Notes; Basic Information - Fujitsu PRIMERGY RX2450 M1 Upgrade And Maintenance Manual

Table of Contents

Advertisement

6

Power supply unit (PSU)

6.1

Safety notes

CAUTION
Do not disassemble the PSU. Doing so may cause electric shock.
Areas around the PSU may remain extremely hot after shutdown.
After shutting down the server, wait for hot components to cool
down before removing the PSU.
When installing a PSU, ensure that the connector of the PSU is not
damaged or bent.
The PSU is heavy, so handle it carefully. If you drop it by mistake,
injuries may result.
For more information, see
6.2

Basic information

AC PSU
The server is equipped with two hot-plug AC PSUs.
In its basic configuration, the server has two PSUs that adjusts automatically to
any mains voltage in the range of 100 V - 127 V and 200 V - 240 V. The
second PSU is installed to serve as a redundant supply. If one PSU fails, the
second PSU in the redundant configuration ensures operation can continue
uninterrupted and the defective PSU can be replaced during operation
(hotplug).
CAUTION
The AC PSU adjusts automatically to any mains voltage in the range
from 100 V - 240 V (AC PSU Platinum) or 200 V - 240 V (AC PSU
Titanium).
You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
RX2450 M1
"Important information" on page
Upgrade and Maintenance Manual
25.