Extending The Server Out Of The Rack - Fujitsu PRIMERGY RX2450 M1 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Basic hardware procedures
4.4.2

Extending the server out of the rack

CAUTION
Use the anti-tilt plate to prevent the rack from tipping when
installing the rack. Pulling the server out of the rack without having
installed the anti-tilt plate may cause the rack to tip over.
Be careful not to pinch fingers or clothes when sliding out the
server or pushing it back. Failure to do so may cause injury.
For maintenance procedures on the system board the rack must be
pulled out of the server and put on a even surface.
Be careful not to damage the rack rails when sliding out the server
or pushing it back. Damaged rack rails may cause injury.
For more information, see
▶ Disconnect all external cables from the I/O panel and expansion cards.
Before removing the power and external cables, take a note where
each cable is installed. Ensure that each cable is reinstalled where it
was installed before the replacement.
▶ If you are not using a cable management arm (CMA kit), ensure that the rear
cables are long enough not to be strained or damaged when extending the
server out of the rack.
Figure 4: Extending the server out of the rack
40
"Important information" on page
Upgrade and Maintenance Manual
25.
RX2450 M1