Drive Motor Cable Schematic; Procedure - Precor Experience 600 Series Service Manual

Hide thumbs Also See for Experience 600 Series:
Table of Contents

Advertisement

Drive Motor Cable Schematic

Procedure

Review entire procedure before starting.
Removal Instructions
1. Switch the power OFF and
2. Remove the hood cover, see
3. Disconnect the Motor Controller "MTH" and "MOTOR" electrical connections:
a. Remove the two left side
ers. Then slide the MC base to the left and remove the MC from the fasteners,
see
"Motor Controller (MC) Replacement" on page
b. Lift the front of the MC just enough to access and disconnect the MC "MTH"
3
I/O
connector. Then lift the rear of the MC just enough to access and dis-
connect the MC "MOTOR" I/O connector.
c. Remove the MOTOR interface cable from the three frame routing cable
clamps.
1
Disconnect a device power cord plug or cable connector from the power receptacle or out-
let.
2
Motor controller, motor controller unit, or motor controller module: used on treadmills, con-
tains the LPCA and motor controller functionality.
3
Input and Output Interface.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
1
unplug
the power cord.
"Hood Cover Replacement" on page
2
MC
fasteners and loosen the two right side fasten-
6 Replacement Procedures
Drive Motor Replacement
82.