Startup [A] - Mitsubishi Electric MELSERVO-J5 User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

■For absolute position detection system
The magnetic pole detection is required in the following cases.
• When the system is set up (at initial startup of equipment)
• When the Z-phase pulse of the direct drive motor manufactured by Mitsubishi Electric is not turned on at the system setup
(When the Z-phase pulse of the direct drive motor can be turned on manually, the magnetic pole detection is not required.)
• After a direct drive motor is replaced
• When [AL. 025 Absolute position erased] has occurred
Turn on the Z-phase pulse of the direct drive motor manufactured by Mitsubishi Electric in the JOG operation from the
controller after the magnetic pole detection.
1.
Execute the magnetic pole detection. Refer to the following.
Page 405 For incremental system
2.
After the completion of the magnetic pole detection, change [Pr. PL01.0 Servo motor magnetic pole detection selection]
to "0" (magnetic pole detection disabled).
Servo parameter
PL01.0
To omit magnetic pole detection at each power-on, after magnetic pole detection, turn on the Z-phase pulse of the direct drive
motor in the JOG operation and set [Pr. PL01.0] to "0" (magnetic pole detection disabled).
11.3

Startup [A]

When using a direct drive motor, set [Pr. PA01.1 Operation mode selection] to "6" (Direct drive motor control mode).
After power-on, the Z-phase mark of the direct drive motor manufactured by Mitsubishi Electric must pass the connector area
once. In a system which prevents the direct drive motor from making a full rotation or more, install the direct drive motor in a
position where the Z-phase mark can pass over the connector area.
11 USING A DIRECT DRIVE MOTOR
406
11.3 Startup [A]
Description
Servo motor magnetic pole detection selection
0: Magnetic pole detection disabled
1: Magnetic pole detection at initial servo-on after cycling the power
5: Magnetic pole detection at every servo-on
Initial value: 1 (magnetic pole detection at initial servo-on after cycling the power)