■MR-J5-200_/MR-J5-350_/MR-J5-500_/MR-J5-700_/MR-J5W2-77G_/MR-J5W2-1010G_/MR-
J5W3-444G_
3-phase or 1-phase
200 V AC to
240 V AC
*1 For the power supply specifications, refer to "Servo amplifier standard specifications" in User's Manual (Introduction).
*2 Use the magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of contacts) of
80 ms or less (160 ms or less for 5 kW or more). The bus voltage may drop depending on the main circuit power supply voltage and
operation pattern, causing a dynamic brake deceleration during a forced stop deceleration. If dynamic brake deceleration is not required,
delay the time to turn off the magnetic contactor.
*3 Operating the on switch and off switch with the DC power supply meets IEC/EN 60204-1 requirements.
*4 Do not share the 24 V DC power supply for interface with a magnetic contactor. Use the power supply designed exclusively for the
magnetic contactor.
*5 If wires used for L11 and L21 are thinner than wires used for L1, L2, L3, and N-, use a fuse.
Page 223 Using servo amplifier with DC power supply input
*6 When connecting a linear servo motor that has a thermal protector, add a contact that interlocks with the thermal protector output of the
linear servo motor.
3 SIGNALS AND WIRING
42
3.1 Example power circuit connections
Malfunction
RA1
24 V DC
*1
MCCB
+
AC/DC
converter
(283 V DC to
-
340 V DC)
*5
Servo motor
overheat
*6
protection
OFF
RA2
Emergency stop switch
Servo amplifier
*3*4
*2
MC
L1
L2
L3
N-
L11
L21
MC
ON
MC
SK