Mitsubishi Electric MELSERVO-J5 User Manual page 223

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

For main circuit power supply [WG]
■MR-J5W2-_G_
Total output
Total
of rotary
continuous
servo motors
thrust of
linear servo
motors
300 W or less
From over 300 W
150 N or less
to 600 W
Over 600 W
From over 150 N
1 kW or less
to 300 N
Over 1 kW
From over 300 N
2 kW or less
to 720 N
*1 To comply with the IEC/EN/UL/CSA standards, refer to the MR-J5 Safety Instructions and Precautions for AC Servos (IB(NA)-0300391)
for selection of molded-case circuit breakers and fuses.
*2 Use the magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of contacts) of
80 ms or less.
*3 The molded-case circuit breaker is the same regardless of whether a power factor improving AC reactor is used.
*4 Use a molded-case circuit breaker that has operation characteristics equal to or higher than Mitsubishi Electric general-purpose
products.
■MR-J5W3-_G_
Total output
Total
of rotary
continuous
servo motors
thrust of
linear servo
motors
450 W or less
150 N or less
From over 450 W
From over 150 N
to 800 W
to 300 N
From over 800 W
From over 300 N
to 1.5 kW
to 450 N
*1 To comply with the IEC/EN/UL/CSA standards, refer to the MR-J5 Safety Instructions and Precautions for AC Servos (IB(NA)-0300391)
for selection of molded-case circuit breakers and fuses.
*2 Use the magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of contacts) of
80 ms or less.
*3 The molded-case circuit breaker is the same regardless of whether a power factor improving AC reactor is used.
*4 Use a molded-case circuit breaker that has operation characteristics equal to or higher than Mitsubishi Electric general-purpose
products.
A motor circuit breaker (Type E combination motor controller) can also be used instead of a molded-case circuit breaker.
Use the motor circuit breaker (Type E combination motor controller) with the line side terminal adapter UT-CV3 and the short-
circuit indicator unit UT-TU.
Servo amplifier
Rated input voltage
AC [V]
MR-J5W2-22G_
200 to 240
MR-J5W2-44G_
MR-J5W2-77G_
MR-J5W2-1010G_
MR-J5W3-222G_
MR-J5W3-444G_
Total output
Molded-case circuit breaker
*1*3*4
of direct drive
motors
Frame, rated
current
30 to 125 A frame 5 A
100 W or less
30 to 125 A frame 10 A
From over 100 W
30 to 125 A frame 15 A
to 252 W
From over 252 W
30 to 125 A frame 20 A
to 838 W
Total output
Molded-case circuit breaker
*1*3*4
of direct drive
motors
Frame, rated
current
30 to 125 A frame 10 A
252 W or less
30 to 125 A frame 15 A
From over 252 W
30 to 125 A frame 20 A
to 378 W
Input phase
Motor circuit breaker (Type E combination motor
controller)
Model
3-phase
MMP-T32
Fuse
Voltage
Class
AC [V]
240
T
Fuse
Voltage
Class
AC [V]
240
T
Rated voltage
AC [V]
240
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.10 Molded-case circuit breakers, fuses, magnetic contactors
Magnetic
contactor
*2
Current
Voltage
[A]
AC [V]
15
300
S-T10
20
20
30
S-T21
Magnetic
contactor
*2
Current
Voltage
[A]
AC [V]
20
300
S-T10
20
30
S-T21
SCCR [kA]
Rated current
[A] (heater
design)
6.3
50
8
13
18
8
13
6
221

Advertisement

Table of Contents
loading

Table of Contents