Mr-Cm Simple Converter; Combination Of Simple Converter And Servo Amplifier; Servo Amplifier Setting When Using A Simple Converter; Simple Converter Standard Specifications - Mitsubishi Electric MELSERVO-J5 User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

6.3

MR-CM simple converter

Combination of simple converter and servo amplifier

Simple converters cannot be used with 400 V class servo amplifiers.
Selection method
Select a servo amplifier for connection that meets the following conditions.
• Connectable servo amplifier models
MR-J5-10_ to MR-J5-200_, MR-J5W2-22G_ to MR-J5W2-1010G_, MR-J5W3-222G_/MR-J5W3-444G_
• The sum of rated capacities of connected servo amplifiers [kW] ≤ 3 kW (MR-CM3K rated output)
For multi-axis servo amplifiers, the calculation uses the sum of the rated capacities of all axes as the rated capacity of one
servo amplifier.
• Number of connectable servo amplifiers to one MR-CM3K ≤ 6
A multi-axis servo amplifier is counted as one servo amplifier unit, rather than the number of axes.

Servo amplifier setting when using a simple converter

When using a simple converter, set [Pr. PA02.4] of the servo amplifier connected in the latter stage to "1" (simple converter is
used). If the simple converter is used without setting [Pr. PA02.4], unexpected alarms may occur.
The simple converter and the external regenerative option connected to the servo amplifier can be used together. To use an
external regenerative option, set [Pr. PA02.0-1]. Note that the simple converter does not have a regenerative function. Also,
an external regenerative option cannot be connected to the simple converter.

Simple converter standard specifications

Model
Converter output
Main circuit power supply
input
Overheat detection
function
Applicable servo amplifier
Maximum number of connectable servo amplifiers
Total capacity of connectable servo amplifiers
Continuous rating
Instantaneous maximum rating
IP rating
Close mounting
Mass
Wire size
Total wiring length from P4/N- of simple converter to P4/N- of servo
amplifier
*1 The value when a 3-phase power supply input is used
6 OPTIONS AND PERIPHERAL EQUIPMENT
192
6.3 MR-CM simple converter
Rated voltage
Rated current
Voltage/Frequency
Rated current
Permissible voltage fluctuation
Thermal sensor
Contact
Maximum voltage
specifications
Maximum current
Minimum current
Maximum capacity
3-phase power supply input
L1/L2/L3/PE
P4/N-
MR-CM3K
270 V DC to 324 V DC
*1
20 A
3-phase 200 V AC to 240 V AC, 50/60 Hz
*1
16 A
3-phase 170 V AC to 264 V AC
The contact between TH1 and TH2 opens if abnormal overheating occurs.
110 V AC/DC
0.3 A/20 V DC
0.1 mA/1 V DC
6 VA
MR-J5-10_ to MR-J5-200_
MR-J5W2-22G_ to MR-J5W2-1010G_
MR-J5W3-222G_, MR-J5W3-444G_
6
3 kW
3 kW
9 kW
IP20
Possible
0.7 kg
2
2
2 mm
to 3.5 mm
(AWG 14 to 12)
2
2
2 mm
to 3.5 mm
(AWG 14 to 12)
5 m or less

Advertisement

Table of Contents
loading

Table of Contents