Homing
■Dog type homing
Set the creep speed of homing in advance to prevent shock from hitting the machine. On detection of a zero pulse, CR
(homing) is turned from off to on. At the same time, the servo amplifier clears the droop pulses, comes to a sudden stop, and
stores the stop position into the non-volatile memory as the home position absolute position data.
CR should be turned on after checking that INP has turned on. If this condition is not satisfied, [AL. 096 Home position setting
warning] occurs. If homing is performed correctly, the alarm is automatically canceled. The number of homing times is limited
to 100000.
Servo motor
DOG (Proximity dog)
INP (In-position)
CR (Home position setting)
ABSB0 (ABS transmission data bit 0)
ABSB1 (ABS transmission data bit 1)
ABSV (Absolute position undetermined)
Control circuit power supply
ON
OFF
ON
OFF
ON
OFF
ON
OFF
20 ms or more
ON
OFF
ON
OFF
Proximity dog
20 ms or more
7 ABSOLUTE POSITION DETECTION SYSTEM
7.3 Absolute position detection system by DIO [A]