Generated loss

Servo amplifier generated heat
The following tables indicate the losses generated by servo amplifiers under rated load. For thermal design of an enclosed
type cabinet, use the values in the tables in consideration for the worst operating conditions. The actual amount of generated
heat depends on the frequency of operation and will be between the "At rated output" and "At servo-off" values.
■200 V class
• 1-axis servo amplifier
Servo amplifier
MR-J5-10_
MR-J5-20_
MR-J5-40_
MR-J5-60_
MR-J5-70_
MR-J5-100_
MR-J5-200_
MR-J5-350_
MR-J5-500_
MR-J5-700_
• Multi-axis servo amplifier
Servo amplifier
MR-J5W2-22G_
MR-J5W2-44G_
MR-J5W2-77G_
MR-J5W2-1010G_
MR-J5W3-222G_
MR-J5W2-444G_
*1 The values stated for heat generated by the servo amplifier do not take into account the heat generated during regeneration. To
calculate heat generated by the regenerative option, refer to the following.
Page 177 Regenerative option
■400 V class
Servo amplifier
MR-J5-60_4_
MR-J5-100_4_
MR-J5-200_4_
MR-J5-350_4_
*1 The values stated for heat generated by the servo amplifier do not take into account the heat generated during regeneration. To
calculate heat generated by the regenerative option, refer to the following.
Page 177 Regenerative option
5 CHARACTERISTICS
128
5.2 Power supply capacity and generated loss
Servo amplifier-generated heat [W]
At rated output
25
25
35
40
50
50
90
130
195
300
Servo amplifier-generated heat [W]
At rated output
Connected to one axis: 30
Connected to two axes: 40
Connected to one axis: 40
Connected to two axes: 60
Connected to one axis: 55
Connected to two axes: 90
Connected to one axis: 55
Connected to two axes: 90
Connected to one axis: 35
Connected to two axes: 45
Connected to three axes: 55
Connected to one axis: 45
Connected to two axes: 65
Connected to three axes: 85
Servo amplifier-generated heat [W]
At rated output
40
60
90
160
*1
At servo-off
15
15
15
15
15
15
20
20
25
25
*1
At servo-off
20
20
20
20
25
25
*1
At servo-off
18
18
20
20
Area required for heat
2
dissipation [m
]
0.5
0.5
0.7
0.8
1.0
1.0
1.8
2.6
3.9
6.0
Area required for heat
2
dissipation [m
]
0.8
1.2
1.8
2.7

Advertisement