CCESSING THE
The initial step for managing the SG-1 Service Gateway System is to log on locally to an SCC or rear I/O port (if a
rear I/O card option is used) and set an IP address to allow for remote management via a Telnet session. This IP
address should place the SG-1 system on the same subnet as a router or other device to which it connects
upstream through its Ethernet port.
C
ONNECTING TO THE
Complete the following procedure to connect to the Craft port.
Step
1
Connect one end of a straight-thru Ethernet cable to the front of the SCC or the COM 1 port of a rear I/O,
if a rear I/O card is installed. Connect the other end of the straight-thru Ethernet cable to the DB9/RJ45
connector (provided in the SG-1 shipment) and then to the PC's COM1 or COM2 port.
2
Power up the ASCII terminal or PC.
Please refer to the appropriate SCC installation manual for more detailed installation instructions, including the
location of the respective SCC Craft port and a description of the SCC Craft port connector pin-outs.
L
OGGING ON TO THE
Complete the following procedure to log on to the Craft port.
Note:
If the keyboard remains inactive for five minutes, the command-line interface Inactivity Timer
automatically logs the current user off. If this happens, log on to the command-line interface again. If
debugging is activated, you may have to press CTRL+C to access the login prompt.
Username
technician
supervisor
operator
viewer
If you are using a PC as a terminal, use a terminal emulation program such as HyperTerminal or Procomm™. Refer
to your terminal emulation program's documentation for instructions.
Step
1
Configure the terminal or the PC terminal emulation program as follows:
• Baud rate: 19200 bps
• Data bits: 8
• Parity: none
• Stop bits: 1
• Flow control: none
2
When using a PC, select the COM setting of the port to which the RS-232 cable is connected (for
example, COM1 or COM2) using the terminal emulation program.
SG1-UM-8500-03
C
L
OMMAND
INE
C
P
RAFT
ORT
C
P
RAFT
ORT
Table 4-1. Default Username/Password
ggcon
sg1
Popgate
Popgate
I
NTERFACE
Action
Password
Action
Chapter
Authority
Full-access read/write
Read/write to second level
Read-only to first level with user
drop capability
First-level show capabilities
4
4-1