ADC Release 3.1 User Manual page 483

Release 3.1 gui
Table of Contents

Advertisement

TAP-100
Page 20 of 23
ALARM
SEVERITY
MESSAGE
Unavailable
Informational
Seconds
Alert
Path
Threshold
Crossing
Alert
UAS-PTca
Unavailable
Informational
Seconds
Alert
Threshold
Crossing
Alert
UASTca
1. After determining the alarm type, locate the associated interface in Figure-1 below to
determine each alarm type origination point in an NE.
1152700 Issue 1 February 2001 Section 2 Operations and Maintenance
Table 4-1. Alarm Identifications, continued
IMPACT
DESCRIPTION
Service
Unavailable seconds
Degradation
threshold crossing alert for
path layer. Path layer was
unavailable for more
seconds than the threshold
was set for. UAS overrides
all other error counts.
Service
T3 unavailable seconds
Degradation
threshold crossing alert. T3
signal was unavailable for
more seconds than the
threshold was set for. UAS
overrides all other error
counts.
SUGGESTED COURSE OF
ACTION
Check input source and
transmitter at far end node.
Check input source.
Page 2-439