ADC Release 3.1 User Manual page 469

Release 3.1 gui
Table of Contents

Advertisement

TAP-100
Page 6 of 23
ALARM
SEVERITY
MESSAGE
Code
Information
Violation
al Alert
Threshold
Crossing
Alert
CV-Stca
Configurat
Minor –
ion Failure
currently an
information
Configurati
al alert
onFailure
Control
Information
Slip
al Alert
Seconds
Threshold
Crossing
Alert
CSSTca
CRC
Information
Threshold
al Alert
Crossing
Alert
CRCErrorT
ca
Degraded
Information
Minutes
al Alert
Threshold
Crossing
Alert
DegradMin
uteTca
1152700 Issue 1 February 2001 Section 2 Operations and Maintenance
Table 4-1. Alarm Identifications, continued
IMPACT
DESCRIPTION
Service
Coding violation threshold
Degradation
crossing alert for section
layer. A bit of information
has changed in the
transmission from the
previous STE causing
Section Code Violations
(CVS) that have exceeded
the user definable threshold
level. Causes a CVL at the
line terminating equipment.
Installation
A request to configure a
Eror
card or port has failed.
Service
DSX1 alarm: The timing
Degradation
Release is changing too
much.
Service
Cyclic Redundancy Check
Degradation
has errors that have
exceeded user definable
levels.
Service
The input signal power
Degradation
level has dropped over a
user definable amount of
time.
SUGGESTED COURSE OF ACTION
Check input levels and signal
sources. Increase threshold
settings if necessary. Check
local requirements for proper
levels.
Check configuration status,
verify physical equipment is
available and try again.
Check timing source signal.
T1 frames may be bad at the
far end or near end. Check
signal inputs and line levels.
Check power level at input,
verify cleanliness of fiber
connections, adjust attenuator
if equipped, and check transmit
end output power level and
replace card if necessary.
(continued)