ALARM
SEVERITY
MESSAGE
Shelf
Informational
Controller
Alert
EIM 1
Removed
EIMSlot1R
emoved
Shelf
Informational
Controller
Alert
EIM 18
Removed
EIMSlot18
Removed
Signal
Minor
Degraded
Software
Informational
Downloadi
Alert
ng Failed
SWDownlo
adFailed
Sync
Major –
Message
currently an
Changed
informational
alert.
SyncMessa
geChanged
Sync
Major –
Reference
currently an
Failure
informational
alert.
SyncRefere
nceFailed
T1
Informational
Loopback
Alert
DS1Loopba
ck
T1 Yellow
Minor
Alarm
DS1Rai
1152700 Issue 1 February 2001 Section 2 Operations and Maintenance
Table 4-1. Alarm Identifications, continued
IMPACT
DESCRIPTION
Installation
SC EIM in slot one which
Information
provides hardwired alarm
inputs and outputs, remote
ACO activation, and
timing reference inputs
(BITS), cannot be found .
Installation
SC EIM in slot 18 which
Information
provides backplane bus
termination, Telnet
connection to the node,
and shelf addressing, has
been physically pulled
from the backplane.
Could be
Input signal strength is
Service
degraded. Possibly a fiber
Affecting.
problem or transmitter.
Installation
NMIC unable to
Information
download software
successfully to the NE.
Installation
SONET sync message (S1
Error
byte) changed.
Service
Timing reference that the
Affecting
network element clocks
off of has failed.
Service
T1 Loopback Pseudo
Affecting
Random Pattern. Indicates
a loopback condition has
been initiated by a user.
Not service
DSX1 Alarm: Remote
affecting
Alarm Indication.
Indicates a problem at the
CPE transmitter.
SUGGESTED COURSE OF ACTION
Buses are probably not
functioning properly because
the Bus Terminating EIM (B-
TEIM) in slot 18 at the rear of
the shelf or the SC in slot 1 has
been physically removed from
the backplane.
Buses are probably not
functioning properly because
the Bus Terminating EIM (B-
TEIM) in slot 18 at the rear of
the shelf or the SC in slot 18
has been physically removed
from the backplane.
Check fiber path for damage or
bends and check attenuation
and transmitter output.
Check FTP connection and NE
status.
No suggestions.
Retrieve timing source
information and check reference
input (BITS, 622-RIC, 155-
CRS).
Check for troubleshooting
activity by other users and
release loopback if necessary.
Check card and output level of
CPE equipment. Replace as
needed per local practices.
(continued)
Page 2-437
© 2000, ADC Telecommunications, Inc.