ADC Release 3.1 User Manual page 478

Release 3.1 gui
Table of Contents

Advertisement

1152700 Issue 1 February 2001 Section 2 Operations and Maintenance
ALARM
SEVERITY
MESSAGE
Primary
Major
Derived
DS1 Source
Failed
Protection
Minor
Switch Bytes
Failure
ProtectionSwi
tchBytesFailu
re
Protection
Minor –
Switch
currently an
Failure
information
al alert.
ProtSwitchF
ailed
Protection
Information
Switch
al
Successful
ProtSwitchS
uccessful
Protocol
Information
Error
al Alert
Threshold
Crossing
Alert
ProtocolErro
rTca
Remote
Major
Failure
Indication
RFI
Page 2-434
© 2000, ADC Telecommunications, Inc.
Table 4-1. Alarm Identifications, continued
IMPACT
DESCRIPTION
Not Service
The reference source for
Affecting
the primary clock has
failed.
Installation
Inconsistent APS byte or
Error
invalid code.
Installation
User initiated or automatic
Error
protection switch failed.
Not Service
Protection switch
Affecting
completed successfully.
Service
Protocol error threshold has
Degradation
been crossed.
Service
Far end has detected AIS at
affecting
the DSX level.
TAP-100
Page 15 of 23
SUGGESTED COURSE OF ACTION
Check source (external, optical
in, or other AIC card) for
alarms and correct as
necessary.
Automatic Protection Switch
(APS) byte is inconsistent with
the expected code. Check
facility interconnections and
verify switching modes match
at each end (i.e., 1:1, 1+1,
1:N).
Check protection group for
previously failed/switched
working card, lockout of
protect, or failed protect card.
PEIM must be installed at the
rear of the shelf at the
protection slot for 1:N
protection groups.
User initiated or automatic
protection switch was
completed. No action
necessary.
Caused by the following: 1)
Out of range VPI/VCI, (2)
Invalid PTI values (6 and 7),
and 3) Unassigned VPI/VCI
values. Check the connection
VPI/VCI to make sure the
provisioning is correct for the
expected traffic stream..
RFI is a near end notification
of a remote failure. For
example, a LOS occurs at the
near end, a RFI line and path is
sent in the reverse direction to
the remote node. An RFI line
is sent if the network element
is a line terminating element
while a RFI path is sent if the
netork element is a path
terminating element.
(continued)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cellworx stn

Table of Contents