Set 622 Ring Card Configuration - ADC Release 3.1 User Manual

Release 3.1 gui
Table of Contents

Advertisement

1152700 Issue 1 February 2001 Section 2 Operation and Maintenance
DLP-751
Page 1 of 3
SET 622 RING INTERFACE CARD (RIC) CONFIGURATION
Summary: This procedure details the steps required to set the 622 Ring interface card
configurations utilizing the Cellworx STN Phase 3.1 shelf level Graphical User Interface (GUI).
User must the have GUI launched and accessed the shelf level GUI display per NTP-006 prior to
performing this procedure.
1. Double click on the 622 RIC located in slot 16 or 17 in the shelf level GUI "Chassis
View"at the top of the window.
2. The 622 RIC display appears as shown in Figure 751-1. The Administrative State of the
card and port should be "Unlocked" if in service and cannot be set using the GUI. If two
RICs were set to "Locked", the node could be isolated requiring a complete ring turn up.
3. Set the rest of the configuration options for the card and port using Table 751-1 for
descriptions of the options.
4. Select the Apply button at the bottom of the window to send the new configuration data to
the shelf controller.
Note: Selecting Chassis View will return the user to the previous window without
closing the 622 RIC window. Selecting Refresh will update the current window display
and all the selections last recorded by the Shelf Controller card. Selecting Close will
close this window.
5. Repeat steps 1 through 5 the second 622 RIC card installed in the shelf.
Stop! You have completed this procedure.